Skip to main content

Your specification

See below for your natural fibre insulation specification.

For more detailed information and more accurate U-value calculations please take this specification to your chosen supplier. See asbp.org.uk/group/natural-fibre-insulation for a list of NFI suppliers.

  • – Existing masonry wall
  • – 5-15mm Lime based levelling plaster, as required.
  • – 100mm wood fibre board
  • – 6mm Lime plaster, incorporating fibreglass mesh
  • – 2mm lime plaster finish coat
  • – Breathable paint
  • – Interior
  • -Mur de maçonnerie existant
  • -Enduit de nivellement à base de chaux de 5 à 15 mm, selon les besoins.
  • -Panneau de fibres de bois de 100 mm
  • -Enduit à la chaux de 6 mm, incorporant un treillis en fibre de verre
  • -Enduit de finition à la chaux 2 mm
  • -Peinture respirante
  • -Intérieur
  • The specification above will achieve a U-value of 0.32 W/m2K
  • A WUFI simulation should be undertaken for the specific project conditions
  • Pour cette spécification R = 3.12 m2K/W
  • Une simulation WUFI doit être entreprise pour les conditions spécifiques du projet