Skip to main content

Your specification

See below for your natural fibre insulation specification.

For more detailed information and more accurate U-value calculations please take this specification to your chosen supplier. See asbp.org.uk/group/natural-fibre-insulation for a list of NFI suppliers.

  • -Exterior
  • -10mm 2-coat Lime render
  • -180mm renderable wood fibre board, fixed back to masonry
  • -Bonding coat render
  • -215mm solid brick wall
  • -Internal plaster
  • -Interior
  • -Extérieur
  • -Enduit Chaux 2 couches 10mm
  • -Panneau de fibre de bois 180 mm enduit, fixé à la maçonnerie
  • -Enduit de liaison
  • -Mur de briques pleines de 215 mm
  • -Plâtre interne
  • -Intérieur
  • The specification above will achieve a U-value of 0.20 W/m2K
  • Pour cette spécification R = 5.0 m2K/W