Your specification
See below for your natural fibre insulation specification.
For more detailed information and more accurate U-value calculations please take this specification to your chosen supplier. See asbp.org.uk/group/natural-fibre-insulation for a list of NFI suppliers.
- -Exterior
- -10mm 2-coat Lime render
- -180mm renderable wood fibre board, fixed back to masonry
- -Bonding coat render
- -215mm solid brick wall
- -Internal plaster
- -Interior
- -Extérieur
- -Enduit Chaux 2 couches 10mm
- -Panneau de fibre de bois 180 mm enduit, fixé à la maçonnerie
- -Enduit de liaison
- -Mur de briques pleines de 215 mm
- -Plâtre interne
- -Intérieur
- The specification above will achieve a U-value of 0.20 W/m2K
- Pour cette spécification R = 5.0 m2K/W