See below for your natural fibre insulation specification.

For more detailed information and more accurate U-value calculations please take this specification to your chosen supplier. See asbp.org.uk/group/natural-fibre-insulation for a list of NFI suppliers.

-Exterior
-Timber cladding
-50mm counter-battens
-Breathable membrane
-100mm T&G wood fibre sarking board, mechanically fixed
-100mm Square edge wood fibre board, mechanically fixed
-10-15mm lime levelling render (if required)
-Existing 225mm brick wall or 450mm natural stone wall

-Extérieur
-Bardage en bois
-Contre-lattes de 50 mm
-Membrane respirante
-Panneau de sous-toiture en fibre de bois T&G de 100 mm, fixé mécaniquement
-Panneau de fibres de bois à bord carré de 100 mm, fixé mécaniquement
-Enduit de nivellement à la chaux 10-15 mm (si nécessaire)
-Mur en brique existant de 225 mm ou mur en pierre naturelle de 450 mm

  • The specification above would achieve a U-value of 0.177 W/m2K
  • Pour cette spécification R = 5.65 m2K/W