Skip to main content

Your specification

See below for your natural fibre insulation specification.

For more detailed information and more accurate U-value calculations please take this specification to your chosen supplier. See asbp.org.uk/group/natural-fibre-insulation for a list of NFI suppliers.

  • Exterior
  • Tiles
  • battens
  • Bitumen felt
  • 100mm rafters @ 400mm centres, with 50mm flexible wood fibre insulation between.
  • 50mm ventilated void above insulation and between rafters.
  • 50mm battens @ 600mm centres, filled with flexible wood fibre insulation
  • 50mm counter-battens @ 600mm centres, filled with flexible wood fibre insulation
  • Vapour control and airtightness membrane, taped and sealed
  • 12mm plasterboard
  • Interior
  • Extérieur
  • Carrelage
  • lattes
  • Feutre de bitume
  • Chevrons de 100 mm à 400 mm d’entraxe, avec une isolation flexible en fibre de bois de 50 mm entre les deux.
  • Vide ventilé de 50 mm au-dessus de l’isolant et entre les chevrons.
  • Lattes de 50 mm à 600 mm d’entraxe, remplies d’isolant flexible en fibre de bois
  • Contre-lattes de 50 mm à 600 mm d’entraxe, remplies d’isolant flexible en fibre de bois
  • Membrane pare-vapeur et d’étanchéité à l’air, scotchée et scellée
  • plaque de plâtre 12mm
  • Intérieur
  • The above specification achieves a U-value of 0.26 W/m2K
  • Pour cette spécification R = 3.85 m2K/W